Ce Medical Equipment Syringe Infusion Pump

Characteristics:
1. 4.three" coloration TFT Lcd display screen (LED backlight), with resolution 272×480
two. Three working modes: Rate/Time/Volume method
3. Drug library with 210 varieties of medicine
four. Storage 1500 heritage data
five. Heating function, appropriate for infusing in winter season or there is need for the fluid treatment temperature
6. Help multi language show
7. A variety of noticeable and audible alarm, make infusion a lot more secure
 

Huge Liquid crystal display show, with backlight, suitable for functioning in various ambient light-weight conditions.
Disposable IV set of any brand name is suited for this pump
Three working modes: Rate/Volume/Time mode
Purge, KVO purpose
Heating perform is optional, suited for infusing in wintertime or there is requirement for the medication temperature.
Distant Controller helps make running a lot more hassle-free.
Central checking program is optional, the infusing status of every single pump is displayed in real time at the central station via wireless transmission.
Easy and practical in functioning, intuitive existence of operating standing.
Audible and Seen alarms
Alarm: Infusion CZPT, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Reduced CZPTery, Setting Mistake, AC power off, Idle.
Measurement: 188 mm(L)*198 mm(W)*228 mm(H)
Net Excess weight: 2.2kg

Normal:Drug library, Background document, Heating operate, Drip detector

Optional:SpO2,NIBP

Why we incorporate NIBP &SpO2 to an infusion pump?
NIBP & SpO2 are the most usually employed important indication parameters, we  make them perform as a single, to aid medical doctors minimize value and help save space  which is already very limited in the clinic space.

CZPT data sheet:                                                                            

Pump Sort Drip variety infusion pump
Pumping Way Peristalic fingers
Adjustable Fall Rate Range 1~400 drops/min (stage: 1 drop/min)
Adjustable Quantity Fee Variety one~1200 ml/h (when 1~ninety nine.9 ml/h, stage: .1 ml/h better than 99.9 ml/h, stage: 1 ml/h)
Movement Precision Within 3% much more or significantly less(making use of the IV established appointed by the maker or calibrated substantial good quality IV established)
CZPT precision inside two% a lot more or less
Purge Fee 800 ml/h
KVO Price one ml/h (1~three hundred ml/h)
three ml/h (higher than 300 ml/h)
Infusion Quantity Variety 1 ml~9999.9 ml (step: .one ml)
Highest Accrued Quantity 9999.nine ml (phase: .1 ml)
 
Time Assortment one min~9999 min (action: 1 min)
Occlusion Alarm Threshold Large: 800 mmHg+-two hundred mmHg (106.7kPa+-26.7kPa)
Medium: 500 mmHg+-one hundred mmHg (sixty six.7kPa+-thirteen.3kPa)
Reduced: three hundred mmHg+-100 mmHg (40.7kPa+-thirteen.3kPa)
Alarm Infusion CZPT, Empty, Faulty Sign, Misoperation, Occlusion, Door Open, Air Bubble, Reduced CZPTery, Setting Mistake, AC energy off, Idle.
Air Bubble Detector Technique ultrasonic wave, sensitivity: a lot more than or equivalent
twenty five μL
Fuse F1AL/250V ("F" point out fast,"L" point out low breaking capacity), 2 pcs (put in inside of pump).
Electrical power CZPT AC 85~265V, fifty/60Hz
Internal CZPTery 11.1V rechargeable li-ion battery. Capability:far more than or equal 2000mAh
the pump can work a lot more than 4 hours at the movement charge of 25 ml/h after charging for 8 hours (Medium fee specified by GB 9706.27-2005).
Power significantly less than or equal 40VA
Dimensions 188 mm(L)*198 mm(W)*228 mm(H)
Excess weight two.2KG
CZPT Needs Transportation
Ambient Temperature: -30°C~+55°C
Relative Humidity: 20%~ninety five% (non-condensing)
Atmosphere Pressure: 70kPa~106kPa
Storage
Ambient Temperature: -30°C~+55°C
Relative Humidity: 20%~ninety five%
Environment Force: 70kPa~106kPa
Procedure
Ambient Temperature: +five~+40°C
Relative Humidity: twenty%~90%
Atmosphere Force: 86kPa~106kPas
Calibration function disposable IV established of any manufacturer is suitable for this pump
A few operating modes Fee/Volume/Time manner
Alarm Infusion CZPT, Vacant, Defective Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low CZPTery, Location Error, AC power off, Idle.
infusion checking technique (Optional),
the position of every single pump is exhibited in genuine time at the central station via wi-fi transmission.
4.3 inch shade Lcd screen, with backlight, suited for working in different ambient mild problems.
Exhibit time, battery, infusing standing, mode, charge, target quantity, amassed volume, goal volume, seem volume, stress, office, bed No., I/V set, temperature of treatment

CZPT Specification:

Infusion charge range
Adjustable drop charge selection: 1 /min~four hundred drops/min
                          (step: 1 drop /min)
Adjustable circulation price range: 1ml/h~1200ml/h
                         (stage .1ml/h)
Purge charge: 800ml/h
KVO price: 1ml/h (one~300ml/h)
         3ml/h (higher than 300ml/h)
Infusion volume range: 1ml~9999.9ml (step: .1 ml)
Maximum accumulated quantity: 9999.9ml (step: .1 ml)
Infusion Time selection: 1min~9999min (phase: 1 min)

Infusion precision: Inside of ±3% (employing calibrated large top quality IV set)
                   CZPT precision: in ±2%

Occlusion alarm threshold:
         High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)
Medium: five hundred mmHg ± 100 mmHg (66.7kPa±13.3kPa)
Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)
Alarm: Infusion CZPT, Vacant, Faulty Signal, Misoperation, Occlusion, Door Open up, Air Bubble, Low CZPTery, Setting Error, AC power off, Idle.

NIBP
Variety
Regular deviation: ≤ ±5mmHg
Regular deviation:  ≤ 8mmHg
Adult
         SYS: 40mmHg~280mmHg
         MEAN: 20mmHg~240mmHg
         DIA: 10mmHg~220mmHg
Pediatric
         SYS: 40mmHg~220mmHg
         MEAN: 20mmHg~170mmHg
         DIA: 10mmHg~160mmHg
Neonate
         SYS: 40mmHg~135mmHg
         MEAN: 20mmHg~110mmHg
         DIA: 10mmHg~100mmHg
Static force
         Range: 0mmHg~300mmHg
         Deviation: 3mmHg

Resolution: 1mmHg

NIBP measurement manner
Manual
Cycle (computerized):
Optional interval: 1min, 2min, 3min,4min, 5min, 10min,
15min, 30min, 60min, 90min
Rapidly: continuous NIBP measurement, interval is 5min

NIBP alarm
Higher force alarm: >90mmHg-160mmHg
Minimal strain alarm: <50mmHg-90mmHg
Accuracy: ±5%

Overpressure protection
Adult: 280 mmHg ±10 mmHg
Pediatric: 237 mmHg ±3 mmHg
Neonate: 147 mmHg ±3 mmHg

SpO2
Variety: %~a hundred%
Resolution: one%
Precision: 70% to one hundred%, precision is 2%
          0% to 69%, undefined

SpO2 alarm
Upper limit: a hundred%
Decrease limit: 90%
Alarm price accuracy: 3%
Alarm time precision: 2s

Pulse fee
Selection: 20bpm~300bpm
Resolution: 1bpm
Accuracy: 3bpm

Pulse fee alarm
Higher limit: 120bpm
Lower limit: 50bpm (default)
Alarm worth precision: five%
Alarm time precision: 2s

NIBP Cuff necessity
Xihu (West Lake) Dis.n physique speak to supplies: Waterproof cloth
Size: 515mm(L)×145mm(W), permitted deviation: ±5%

SpO2 sensor
Variety: Finger clip variety
Wire length: 3000mm, authorized deviation: ±5%
Xihu (West Lake) Dis.n physique speak to materials: Silicone

Measurement: 188 mm(L)×198 mm(W)×228 mm(H)
Internet weight: two.2kg

Why pick us:
we acquired production and organization certification from HangZhou meals and Drug Administration
we obtained enterprise license from HangZhou Metropolis Administration of industry and commerce
we acquired items certificate of registration and have checked in the site of SFDA
we have accepted the onsite verify from SFDA each quarter
we finished the instruction of regulations and laws in healthcare equipments discipline
We have effectively-established method about substance acquiring, personnel coaching,keep administration,following-revenue support approach.and many others
We adheres the beliefs of "Assistance Healthier Lifestyle", and our firm spirits are top quality, provider,have confidence in,thanksgiving

 

Ce Medical Equipment Syringe Infusion Pump