Product Description

Strong Powerful Dental Equipment Supply 6 Portable Suction Vacuum Pump

 

Let clinic can breath freely
During dental treatment, the cooling water of modem high speed rotating equipment is result in aerosol that could will be fill all clinic.
this aerosol include various microbes, bacteria and viruses, it can increase the risk of cross infection for dentist. dental suction can solve
this problem, it adopt suction with more or less 300/ min can effective reduce cross infection risk.Return safety, cleaning comfortable clinic
environment let clinic can breath freely.

Return more transparent treatment zone
During dental treatment,due to the use of high speed turbine handpiece and air-Prophy unit, It will be create aerosol in the patients month,
then reduce the ability of treatment zone, series dental suction with 3OOL/min suction power
can return more transparent treatment Zone

Offer comfortable treatment for patient
During patient treatment, inevitable have large of water come into patients
mouth(turbine handpiece cooling water, clean &wound leaning water. and patients
secrection, stimulate patient's nerve, lead to swallowing reaction, f cant make constant
and effective drainage, it ill stop treatment to influence treatment effect
sees dental suction with 300/ min suction power can improve your work efficiency, at
the same time, let patient and you have more comfortable treatment posture

Specification

Voltage

220V 50HZ

Input Power

1500W

Electric current

11A

Motor revolution

2800r/min

Max wind pressure

19kPa

Vacuum degree

-18kPa

Noise

64dB

N.W

70kg

G.W.

100KG

Size of product

92*44*70cm

Packing Size

100*52*76cm

More details photos for you reference

More models for you choose

Model ADS-S370 ADS-S750 ADS-S1100 ADS-S1300 ADS-S1500
Voltage 220V/50Hz 220V/50Hz 220V/50Hz 220V/50Hz 220V/50Hz
Current 2.7A 4.1A 7.5A 5.4A 11A
Pump power 600W 750W 1100W 1300W 1500W
Revolution 2800r/min 2800r/min 2800r/min 2800r/min 2800r/min
Noise 64dB 67dB 69dB 69dB 72dB
Max Vacuum -12kPa -15kPa -18kPa -33kPa -19kPa
Connect dental unit quantity (simultaneous use 60%) 1 2 4 5 6
Connect dental unit quantity (simultaneous use 100%) 1 1 3 4 4
N.W. 26.5KG 25KG 32KG 41KG 70KG
G.W. 37KG 36KG 42KG 52KG 100KG
Product size 37x33x83 CM 49x31x66 CM 48x32x70 CM 51x41x63 CM 92x44x70 CM
Package size 42x40x92CM 54x38x70 CM 61x43x82CM 52x48x70CM 97x52x76 CM

FAQ: 
1. Q: Are you a factory or trading company? 
A: We are factory.We produce dental chair,dental air compressor and xray machine,and it's approved CE certificated. 

2. Q: Where is your factory located? How can I visit there? 
A: Our factory is located in HangZhou City,ZheJiang Province,China,near HangZhou.You can fly to Xihu (West Lake) Dis. airport,you can take tax or metro to HangZhou directly.All our clients,from home or abroad,are warmly welcome to visit us! 

3. Q: How can I get Fob or C&F price? 
A: Normally production time of products is from 2 week to 1 month depending on the quantity ordered. If you are sourcing a product, our representative will give you specific information regarding the lead time. If you need a rush order, contact our representatives to discuss your specific needs. 

4. Q: How long is my warranty and what does it cover? 
A: Carry the full 1 year manufacturer warranty. Each warranty period begins at the date of delivery date and ends after 1 year. The warranty varies by option items and manufacturer All warranty claims will be void due to neglect, lack of maintenance, and/or improper handling. 

5. How can I get the after sevice? How can I get the spare part after 1 year warranty? 
A: We welcome your chats online (Chat or leave message: After service) or e-mail to us regarding any technical or related questions that you may have. And we will offer some free sparts for container order. We gurantee keep dental chair units spare parts offer. 

If you want to know more information about our products welcome to contact us in any time, And welcome to our company! 

Contact
Contact person: Allen Song
 

Applicable Departments: Oral Surgery
Certification: ISO, CE
Type: Cleaning & Filling Teeth Equipments
Material: Aluminum
Certificate: CE
Voltage: 110V/220V
Customization:
Available

|

vacuum pump

What Is the Vacuum Level and How Is It Measured in Vacuum Pumps?

The vacuum level refers to the degree of pressure below atmospheric pressure in a vacuum system. It indicates the level of "emptiness" or the absence of gas molecules in the system. Here's a detailed explanation of vacuum level measurement in vacuum pumps:

Vacuum level is typically measured using pressure units that represent the difference between the pressure in the vacuum system and atmospheric pressure. The most common unit of measurement for vacuum level is the Pascal (Pa), which is the SI unit. Other commonly used units include Torr, millibar (mbar), and inches of mercury (inHg).

Vacuum pumps are equipped with pressure sensors or gauges that measure the pressure within the vacuum system. These gauges are specifically designed to measure the low pressures encountered in vacuum applications. There are several types of pressure gauges used for measuring vacuum levels:

1. Pirani Gauge: Pirani gauges operate based on the thermal conductivity of gases. They consist of a heated element exposed to the vacuum environment. As gas molecules collide with the heated element, they transfer heat away, causing a change in temperature. By measuring the change in temperature, the pressure can be inferred, allowing the determination of the vacuum level.

2. Thermocouple Gauge: Thermocouple gauges utilize the thermal conductivity of gases similar to Pirani gauges. They consist of two dissimilar metal wires joined together, forming a thermocouple. As gas molecules collide with the thermocouple, they cause a temperature difference between the wires, generating a voltage. The voltage is proportional to the pressure and can be calibrated to provide a reading of the vacuum level.

3. Capacitance Manometer: Capacitance manometers measure pressure by detecting the change in capacitance between two electrodes caused by the deflection of a flexible diaphragm. As the pressure in the vacuum system changes, the diaphragm moves, altering the capacitance and providing a measurement of the vacuum level.

4. Ionization Gauge: Ionization gauges operate by ionizing gas molecules in the vacuum system and measuring the resulting electrical current. The ion current is proportional to the pressure, allowing the determination of the vacuum level. There are different types of ionization gauges, such as hot cathode, cold cathode, and Bayard-Alpert gauges.

5. Baratron Gauge: Baratron gauges utilize the principle of capacitance manometry but with a different design. They consist of a pressure-sensing diaphragm separated by a small gap from a reference electrode. The pressure difference between the vacuum system and the reference electrode causes the diaphragm to deflect, changing the capacitance and providing a measurement of the vacuum level.

It's important to note that different types of vacuum pumps may have different pressure ranges and may require specific pressure gauges suitable for their operating conditions. Additionally, vacuum pumps are often equipped with multiple gauges to provide information about the pressure at different stages of the pumping process or in different parts of the system.

In summary, vacuum level refers to the pressure below atmospheric pressure in a vacuum system. It is measured using pressure gauges specifically designed for low-pressure environments. Common types of pressure gauges used in vacuum pumps include Pirani gauges, thermocouple gauges, capacitance manometers, ionization gauges, and Baratron gauges.

\vacuum pump

How Do Vacuum Pumps Assist in Freeze-Drying Processes?

Freeze-drying, also known as lyophilization, is a dehydration technique used in various industries, including pharmaceutical manufacturing. Vacuum pumps play a crucial role in facilitating freeze-drying processes. Here's a detailed explanation:

During freeze-drying, vacuum pumps assist in the removal of water or solvents from pharmaceutical products while preserving their structure and integrity. The freeze-drying process involves three main stages: freezing, primary drying (sublimation), and secondary drying (desorption).

1. Freezing: In the first stage, the pharmaceutical product is frozen to a solid state. Freezing is typically achieved by lowering the temperature of the product below its freezing point. The frozen product is then placed in a vacuum chamber.

2. Primary Drying (Sublimation): Once the product is frozen, the vacuum pump creates a low-pressure environment within the chamber. By reducing the pressure, the boiling point of water or solvents present in the frozen product is lowered, allowing them to transition directly from the solid phase to the vapor phase through a process called sublimation. Sublimation bypasses the liquid phase, preventing potential damage to the product's structure.

The vacuum pump maintains a low-pressure environment by continuously removing the water vapor or solvent vapor generated during sublimation. The vapor is drawn out of the chamber, leaving behind the freeze-dried product. This process preserves the product's original form, texture, and biological activity.

3. Secondary Drying (Desorption): After the majority of the water or solvents have been removed through sublimation, the freeze-dried product may still contain residual moisture or solvents. In the secondary drying stage, the vacuum pump continues to apply vacuum to the chamber, but at a higher temperature. The purpose of this stage is to remove the remaining moisture or solvents through evaporation.

The vacuum pump maintains the low-pressure environment, allowing the residual moisture or solvents to evaporate at a lower temperature than under atmospheric pressure. This prevents potential thermal degradation of the product. Secondary drying further enhances the stability and shelf life of the freeze-dried pharmaceutical product.

By creating and maintaining a low-pressure environment, vacuum pumps enable efficient and controlled sublimation and desorption during the freeze-drying process. They facilitate the removal of water or solvents while minimizing the potential damage to the product's structure and preserving its quality. Vacuum pumps also contribute to the overall speed and efficiency of the freeze-drying process by continuously removing the vapor generated during sublimation and evaporation. The precise control provided by vacuum pumps ensures the production of stable and high-quality freeze-dried pharmaceutical products.

vacuum pump

How Do You Choose the Right Size Vacuum Pump for a Specific Application?

Choosing the right size vacuum pump for a specific application involves considering several factors to ensure optimal performance and efficiency. Here's a detailed explanation:

1. Required Vacuum Level: The first consideration is the desired vacuum level for your application. Different applications have varying vacuum level requirements, ranging from low vacuum to high vacuum or even ultra-high vacuum. Determine the specific vacuum level needed, such as microns of mercury (mmHg) or pascals (Pa), and choose a vacuum pump capable of achieving and maintaining that level.

2. Pumping Speed: The pumping speed, also known as the displacement or flow rate, is the volume of gas a vacuum pump can remove from a system per unit of time. It is typically expressed in liters per second (L/s) or cubic feet per minute (CFM). Consider the required pumping speed for your application, which depends on factors such as the volume of the system, the gas load, and the desired evacuation time.

3. Gas Load and Composition: The type and composition of the gas or vapor being pumped play a significant role in selecting the right vacuum pump. Different pumps have varying capabilities and compatibilities with specific gases. Some pumps may be suitable for pumping only non-reactive gases, while others can handle corrosive gases or vapors. Consider the gas load and its potential impact on the pump's performance and materials of construction.

4. Backing Pump Requirements: In some applications, a vacuum pump may require a backing pump to reach and maintain the desired vacuum level. A backing pump provides a rough vacuum, which is then further processed by the primary vacuum pump. Consider whether your application requires a backing pump and ensure compatibility and proper sizing between the primary pump and the backing pump.

5. System Leakage: Evaluate the potential leakage in your system. If your system has significant leakage, you may need a vacuum pump with a higher pumping speed to compensate for the continuous influx of gas. Additionally, consider the impact of leakage on the required vacuum level and the pump's ability to maintain it.

6. Power Requirements and Operating Cost: Consider the power requirements of the vacuum pump and ensure that your facility can provide the necessary electrical supply. Additionally, assess the operating cost, including energy consumption and maintenance requirements, to choose a pump that aligns with your budget and operational considerations.

7. Size and Space Constraints: Take into account the physical size of the vacuum pump and whether it can fit within the available space in your facility. Consider factors such as pump dimensions, weight, and the need for any additional accessories or support equipment.

8. Manufacturer's Recommendations and Expert Advice: Consult the manufacturer's specifications, guidelines, and recommendations for selecting the right pump for your specific application. Additionally, seek expert advice from vacuum pump specialists or engineers who can provide insights based on their experience and knowledge.

By considering these factors and evaluating the specific requirements of your application, you can select the right size vacuum pump that meets the desired vacuum level, pumping speed, gas compatibility, and other essential criteria. Choosing the appropriate vacuum pump ensures efficient operation, optimal performance, and longevity for your application.

China supplier Strong Powerful Dental Equipment Supply 6 Portable Suction Vacuum Pump   manufacturer China supplier Strong Powerful Dental Equipment Supply 6 Portable Suction Vacuum Pump   manufacturer
editor by CX 2023-11-17